NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Preliminary investigation of heat transfer to water flowing in an electrically heated Inconel tubeA heat-transfer investigation was conducted with water flowing in an electrically heated Inconel tube with an inside diameter of 0.204 inch and a length-diameter ratio of 50 for ranges of Reynolds number up to 100,000 and of entrance pressure up to 200 inches of mercury gage. Correlation of average heat-transfer coefficients was obtained by use of the familiar Nusselt relation, wherein the physical properties of water were evaluated at an average bulk temperature. For conditions in which no boiling occurred, the data gave a good correlation. Runs made in the nucleate-boiling region, however, gave higher values of heat-transfer coefficient than would be predicted by the Nusselt relation.
Document ID
19930086328
Acquisition Source
Legacy CDMS
Document Type
Other
Authors
Kaufman, Samuel J
Isely, Francis D
Date Acquired
August 16, 2013
Publication Date
September 27, 1950
Report/Patent Number
NACA-RM-E50G31
Report Number: NACA-RM-E50G31
Accession Number
93R15618
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.