NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Calibration of the receiver channel for the GOPEX precursor experimentsCalibration measurements for the cooled (253 K) photomultiplier tube (PMT) detector, used on the receiver channel of the transmit/receive (T/R) switch for GOPEX, were conducted in the laboratory. A pulsed frequency-doubled neodymium:yttrium-aluminum-garnet (Nd:YAG) laser was used to direct 532-mn light on the PMT. By monitoring the energy per pulse of the light incident on the PMT, the minimum number of photons detected could be determined. These results agreed with the photon flux back-calculated from the PMT output waveform. Approximately 700 incident photons arriving during a temporal pulse width of approximately 65 nsec were detected with a signal-to-noise ratio (SNR) of approximately 1. Other receiver channel characteristics, such as PMT dark currents, optical transmission, and interference filter sensitivity to angle of light incidence, were also measured.
Document ID
19940009914
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Biswas, A.
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Date Acquired
September 6, 2013
Publication Date
August 15, 1993
Publication Information
Publication: The Telecommunications and Data Acquisition Report
Subject Category
Communications And Radar
Accession Number
94N14387
Funding Number(s)
PROJECT: RTOP 315-91-60-10-03
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.