NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Dosimetric results on EURECADetector packages were exposed on the European Retrievable Carrier (EURECA) as part of the Biostack experiment inside the Exobiology and Radiation Assembly (ERA) and at several locations around EURECA. The packages consist of different plastic nuclear track detectors, nuclear emulsions and thermoluminescence dosimeters (TLD's). Evaluation of these detectors yields data on absorbed dose and particle and LET spectra. Preliminary results of absorbed dose measurements in the EURECA dosimeter packages are reported and compared to results of the LDEF experiments. The highest dose rate measured on EURECA is 63.3 plus or minus 0.4 mGy d(exp -1) behind a shielding thickness of 0.09 g cm(exp -2) in front of the detector package.
Document ID
19950017380
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Reitz, G.
(Deutsche Forschungsanstalt fuer Luft- und Raumfahrt Cologne, Germany)
Date Acquired
September 6, 2013
Publication Date
February 1, 1995
Publication Information
Publication: NASA. Langley Research Center, LDEF: 69 Months in Space. Third Post-Retrieval Symposium, Part 1
Subject Category
Space Radiation
Accession Number
95N23800
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.