Space Shuttle Hypergol Load Determination Using Nonintrusive Ultrasonic FlowmetersSpace Shuttle preflight hypergol oxidizer and fuel loading were monitored using a nonintrusive flow measurement system (NFMS) during preflight operation. A pair of 4-megahertz ultrasonic transducers measured the flow rate using a transit-time flow measurement technique. Using wireless cellular phone technology, flow-rate data was monitored and recorded. Excellent correlation was observed between the flow profiles measured using the proposed nonintrusive ultrasonic flowmeters (UFM's) and those made from conventional intrusive turbine meters (TFM). Based on the preliminary tests, it is concluded that the nonintrusive method of flow measurement has the same or higher accuracy, is simpler, and costs less than the existing TFM. Benefits of UFM's include a highly flexible, cost-effective, reliable, hazard free, and streamlined hypergol operation. Redundant installation of ultrasonic flowmeters was recommended for a few more launches prior to the replacement of the existing TFM.
Document ID
19970001433
Acquisition Source
Kennedy Space Center
Document Type
Technical Memorandum (TM)
Authors
Werlink, Rudolph
(NASA Kennedy Space Center Cocoa Beach, FL United States)
Kelley, Andrew
(NASA Kennedy Space Center Cocoa Beach, FL United States)
Margasahayam, Ravi
(I-NET, Inc. Cocoa Beach, FL United States)
Date Acquired
September 6, 2013
Publication Date
September 1, 1996
Subject Category
Propellants And Fuels
Report/Patent Number
NAS 1.15:111884
NASA-TM-111884
Report Number: NAS 1.15:111884
Report Number: NASA-TM-111884
Accession Number
97N11248
Funding Number(s)
CONTRACT_GRANT: NAS10-11943
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available