NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Upper Body Venous Compliance Exceeds Lower Body Venous Compliance in HumansHuman venous compliance hypothetically decreases from upper to lower body as a mechanism for maintenance of the hydrostatic indifference level 'headward' in the body, near the heart. This maintains cardiac filling pressure, and thus cardiac output and cerebral perfusion, during orthostasis. This project entailed four steps. First, acute whole-body tilting was employed to alter human calf and neck venous volumes. Subjects were tilted on a tilt table equipped with a footplate as follows: 90 deg, 53 deg, 30 deg, 12 deg, O deg, -6 deg, -12 deg, -6 deg, O deg, 12 deg, 30 deg, 53 deg, and 90 deg. Tilt angles were held for 30 sec each, with 10 sec transitions between angles. Neck volume increased and calf volume decreased during head-down tilting, and the opposite occurred during head-up tilt. Second, I sought to cross-validate Katkov and Chestukhin's (1980) measurements of human leg and neck venous pressures during whole-body tilting, so that those data could be used with volume data from the present study to calculate calf and neck venous compliance (compliance = (Delta)volume/(Delta)pressure). Direct measurements of venous pressures during postural chances and whole-body tilting confirmed that the local changes in venous pressures seen by Katkov and Chestukhin (1980) are valid. The present data also confirmed that gravitational changes in calf venous pressure substantially exceed those changes in upper body venous pressure. Third, the volume and pressure data above were used to find that human neck venous compliance exceeds calf venous compliance by a factor of 6, thereby upholding the primary hypothesis. Also, calf and neck venous compliance correlated significantly with each other (r(exp 2) = 0.56). Fourth, I wished to determine whether human calf muscle activation during head-up tilt reduces calf venous compliance. Findings from tilting and from supine assessments of relaxed calf venous compliance were similar, indicating that tilt-induced muscle activation is relatively unimportant. Low calf venous compliance probably results from stiffer venous, skeletal muscle, and connective tissues, and better-developed local and central neural controls of venous distensibility. This research establishes that upper-to-lower body reduction of venous compliance can explain headward positioning of the hydrostatic indifference level in humans.
Document ID
19970003261
Acquisition Source
Ames Research Center
Document Type
Technical Memorandum (TM)
Authors
Watenpaugh, Donald E.
(NASA Ames Research Center Moffett Field, CA United States)
Date Acquired
September 6, 2013
Publication Date
July 1, 1996
Subject Category
Aerospace Medicine
Report/Patent Number
NASA TM-110409
NAS 1.15:110409
A-962296
Report Number: NASA TM-110409
Report Number: NAS 1.15:110409
Report Number: A-962296
Accession Number
97N12016
Funding Number(s)
PROJECT: RTOP 199-14-12-04
PROJECT: RTOP 199-26-12-38
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available