Application of CFD to Explain Anomalous Stall Behavior of the SSME FlowmeterThe Space Shuttle Main Engine (SSME) Fuel Flowmeter is located in the duct between the low and high pressure fuel turbopumps. In the flowmeter the rotation rate of a 4-blade rotor positioned downstream of two flow straighteners is employed to measure the engine fuel flow rate and thereby control the engine mixture ratio via the engine controller. Hence, inaccurate operation of the flowmeter could have serious consequences for SSME engine operation and performance, forcing, for example, tanking of extra fuel to allow for inaccurate flowmeter measurement. Since the current flight flowmeter configuration was incorporated into the SSME in the early eighties, some anomalies in flowmeter behavior have been observed. The initial flowmeter incorporated an "egg crate" design for the two flow straighteners which turn the duct flow to make it more uniform and parallel after it has come out of the 90 degree bend just upstream of the flowmeter.
Document ID
19990036732
Acquisition Source
Marshall Space Flight Center
Document Type
Preprint (Draft being sent to journal)
Authors
Ascoli, E.
(Boeing Co. Canoga Park, CA United States)
Clever, W.
(Boeing Co. Canoga Park, CA United States)
Hadid, A.
(Boeing Co. Canoga Park, CA United States)
Lynch, E. D.
(Boeing Co. Canoga Park, CA United States)
Stewart, M.
(Boeing Co. Canoga Park, CA United States)
Lee, K.
(Rockwell International Science Center Thousand Oaks, CA United States)
Date Acquired
September 6, 2013
Publication Date
January 1, 1999
Subject Category
Fluid Mechanics And Heat Transfer
Funding Number(s)
CONTRACT_GRANT: NAS8-45000
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available