Cable Bundle Wire DeratingThe allowable operating currents of electrical wiring when used in the space vacuum environment is predominantly determined by the maximum operating temperature of the wire insulation. For Kapton insulated wire this value is 200 C. Guidelines provided in the Goddard Space Flight Center (GSFC) Preferred Parts List (PPL) limit the operating current of wire within vacuum to ensure the maximum insulation temperature is not exceeded. For 20 AWG wire, these operating parameters are: (1) 3.7 amps per wire; (2) bundle of 15 or more wires; (3) 70 C environment: and (4) vacuum of 10(exp -5) torr or less. To determine the behavior and temperature of electrical wire at different operating conditions, a thermal vacuum test was performed on a representative electrical harness of the Hubble Space Telescope (HST) power distribution system. This paper describes the test and the results.
Document ID
19990113164
Acquisition Source
Goddard Space Flight Center
Document Type
Reprint (Version printed in journal)
Authors
Lundquist, Ray A.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Leidecker, Henning
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Date Acquired
August 19, 2013
Publication Date
January 1, 1998
Subject Category
Electronics And Electrical Engineering
Meeting Information
Meeting: Space Simulation
Location: Annapolis, MD
Country: United States
Start Date: October 28, 1998
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available