NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Evaluation of Ti-48Al-2Nb Under Fretting ConditionsAn investigation was conducted to examine the fretting behavior of lambda-TiAl (Ti-48Al-2Cr-2Nb) in contact with a nickel-base superalloy (Inconel 718) in air at temperatures from 23 to 550 C. Fretting wear experiments were conducted with 9.4-mm-diameter hemispherical Inconel (IN) 718 pins in contact with Ti-48Al-2Cr-2Nb flats (and the reverse) at loads from 1 to 40 N and fretting frequencies from 50 to 160 Hz with slip amplitudes from 50 to 200 microns for 1 to 20 million fretting cycles. The results were similar for both combinations of pin and flat. Reference fretting wear experiments were also conducted with 9.4-mm-diameter hemispherical Ti-6Al-4V pins in contact with IN718 flats. The interfacial adhesive bonds between Ti-48Al-2Cr-2Nb and IN718 in contact were generally stronger than the cohesive bonds in the cohesively weaker Ti-48Al-2Cr-2Nb. The failed Ti-48Al-2Cr-2Nb subsequently transferred to the IN718 surface at any fretting condition. The wear scars produced on Ti-48Al-2Cr-2Nb contained metallic and oxide wear debris, scratches, plastically deformed asperities, cracks, and fracture pits. Oxide layers readily formed on the Ti-48Al-2Cr-2Nb surface at 550 C, but cracks easily occurred in the oxide layers. Factors including fretting frequency, temperature, slip amplitude, and load influenced the fretting behavior of Ti-48Al-2Cr-2Nb in contact with IN718. The wear volume loss of Ti-48Al-2Cr-2Nb generally decreased with increasing fretting frequency. The increasing rate of oxidation at elevated temperatures up to 200 C led to a drop in wear volume loss at 200 C. However, the fretting wear increased as the temperature was increased from 200 to 550 C. The highest temperatures of 450 and 550 C resulted in oxide film disruption with generation of cracks, loose wear debris, and pits on the Ti-48Al-2Cr-2Nb wear surface. The wear volume loss generally increased as the slip amplitude increased. The wear volume loss also generally increased as the load increased. Increasing slip amplitude and increasing load both tended to produce more metallic wear debris, causing severe abrasive wear in the contacting metals.
Document ID
20010061370
Acquisition Source
Glenn Research Center
Document Type
Preprint (Draft being sent to journal)
Authors
Miyoshi, Kazuhisa
(NASA Glenn Research Center Cleveland, OH United States)
Lerch, Bradley A.
(NASA Glenn Research Center Cleveland, OH United States)
Draper, Susan L.
(NASA Glenn Research Center Cleveland, OH United States)
Raj, Sai V.
(NASA Glenn Research Center Cleveland, OH United States)
Date Acquired
September 7, 2013
Publication Date
January 1, 2001
Subject Category
Metals And Metallic Materials
Meeting Information
Meeting: Third International Symposium on Fretting Fatigue
Location: Nagaoko
Country: Japan
Start Date: May 15, 2001
End Date: May 18, 2001
Sponsors: American Society for Testing and Materials
Funding Number(s)
PROJECT: RTOP 708-24-13
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available