Terahertz NDE Application for Corrosion Detection and Evaluation under Shuttle TilesPulsed Terahertz NDE is being examined as a method to inspect for possible corrosion under Space Shuttle Tiles. Other methods such as ultrasonics, infrared, eddy current and microwave technologies have demonstrable shortcomings for tile NDE. This work applies Terahertz NDE, in the frequency range between 50 GHz and 1 THz, for the inspection of manufactured corrosion samples. The samples consist of induced corrosion spots that range in diameter (2.54 to 15.2 mm) and depth (0.036 to 0.787 mm) in an aluminum substrate material covered with tiles. Results of these measurements are presented for known corrosion flaws both covered and uncovered and for blind tests with unknown corrosion flaws covered with attached tiles. The Terahertz NDE system is shown to detect all artificially manufactured corrosion regions under a Shuttle tile with a depth greater than 0.13 mm.
Document ID
20070016023
Acquisition Source
Langley Research Center
Document Type
Conference Paper
Authors
Anastasi, Robert F. (Army Research Lab. Hampton, VA, United States)
Madaras, Eric I. (NASA Langley Research Center Hampton, VA, United States)
Seebo, Jeffrey P. (Lockheed Martin Corp. Hampton, VA, United States)
Smith, Stephen W. (NASA Langley Research Center Hampton, VA, United States)
Lomness, Janice K. (NASA Kennedy Space Center Cocoa Beach, FL, United States)
Hintze, Paul E. (NASA Kennedy Space Center Cocoa Beach, FL, United States)
Kammerer, Catherine C. (United Space Alliance Cape Canaveral, FL, United States)
Winfree, William P. (NASA Langley Research Center Hampton, VA, United States)
Russell, Richard W. (NASA Kennedy Space Center Cocoa Beach, FL, United States)
Date Acquired
August 23, 2013
Publication Date
January 1, 2007
Subject Category
Spacecraft Design, Testing And Performance
Meeting Information
Meeting: SPIE 14th Annual International Symposium on Smart Structures and Materials and Nondestructive Evaluation and Health Monitoring