Wire Crimp Connectors Verification using Ultrasonic InspectionThe development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.
Document ID
20080013394
Acquisition Source
Langley Research Center
Document Type
Conference Paper
Authors
Cramer, K. Elliott
(NASA Langley Research Center Hampton, VA, United States)
Perey, Daniel F.
(NASA Langley Research Center Hampton, VA, United States)
Yost, William T.
(NASA Langley Research Center Hampton, VA, United States)
Date Acquired
August 24, 2013
Publication Date
January 1, 2007
Subject Category
Mechanical Engineering
Meeting Information
Meeting: IV Pan American Conference for Non Destructive Testing
Location: Buenos Aires
Country: Argentina
Start Date: October 22, 2007
End Date: October 27, 2007
Funding Number(s)
WBS: WBS 698259.02.07.07.02
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available