Fire Chemistry Testing of Spray-On Foam Insulation (SOFI)An experimental study was initiated that included the long-term testing of the following SOFI materials, which make up the majority of the Thermal Protection System of the Shuttle External Tank: NCFI 24-124 (acreage foam) and BX-265 (close-out foam, including the intertank flange and bipod areas). A potential alternate material, NCFI 27-68 (acreage foam with flame retardant removed), was also tested. Fire chemistry testing was completed on samples that were retrieved after aging/weathering at intervals of 3, 6, and 12 months. The testing included three standard test methods: limiting oxygen index (ASTM G125), radiant panel (ASTM E162), and cone calorimeter (ASTM E1354).