Calculation of Dose Deposition in Nanovolumes and Simulation of gamma-H2AX ExperimentsMonte-Carlo track structure simulations can accurately simulate experimental data: a) Frequency of target hits. b) Dose per event. c) Dose per ion. d) Radial dose. The dose is uniform in micrometers sized voxels; at the nanometer scale, the difference in energy deposition between high and low-LET radiations appears. The calculated 3D distribution of dose voxels, combined with chromosomes simulated by random walk is very similar to the distribution of DSB observed with gamma-H2AX experiments. This is further evidenced by applying a visualization threshold on dose.
Document ID
20100039601
Acquisition Source
Johnson Space Center
Document Type
Presentation
Authors
Plante, Ianik (Universities Space Research Association Houston, TX, United States)