Symmetric Phase Only Filtering for Improved DPIV Data ProcessingThe standard approach in Digital Particle Image Velocimetry (DPIV) data processing is to use Fast Fourier Transforms to obtain the cross-correlation of two single exposure subregions, where the location of the cross-correlation peak is representative of the most probable particle displacement across the subregion. This standard DPIV processing technique is analogous to Matched Spatial Filtering, a technique commonly used in optical correlators to perform the crosscorrelation operation. Phase only filtering is a well known variation of Matched Spatial Filtering, which when used to process DPIV image data yields correlation peaks which are narrower and up to an order of magnitude larger than those obtained using traditional DPIV processing. In addition to possessing desirable correlation plane features, phase only filters also provide superior performance in the presence of DC noise in the correlation subregion. When DPIV image subregions contaminated with surface flare light or high background noise levels are processed using phase only filters, the correlation peak pertaining only to the particle displacement is readily detected above any signal stemming from the DC objects. Tedious image masking or background image subtraction are not required. Both theoretical and experimental analyses of the signal-to-noise ratio performance of the filter functions are presented. In addition, a new Symmetric Phase Only Filtering (SPOF) technique, which is a variation on the traditional phase only filtering technique, is described and demonstrated. The SPOF technique exceeds the performance of the traditionally accepted phase only filtering techniques and is easily implemented in standard DPIV FFT based correlation processing with no significant computational performance penalty. An "Automatic" SPOF algorithm is presented which determines when the SPOF is able to provide better signal to noise results than traditional PIV processing. The SPOF based optical correlation processing approach is presented as a new paradigm for more robust cross-correlation processing of low signal-to-noise ratio DPIV image data."
Document ID
20110014486
Acquisition Source
Glenn Research Center
Document Type
Conference Paper
Authors
Wernet, Mark P.
(NASA Glenn Research Center Cleveland, OH, United States)
Date Acquired
August 25, 2013
Publication Date
January 9, 2006
Subject Category
Instrumentation And Photography
Report/Patent Number
AIAA Paper 2006-0042
E-17865
Report Number: AIAA Paper 2006-0042
Report Number: E-17865
Meeting Information
Meeting: 44th AIAA Aerospace Sciences Meeting and Exhibit
Location: Reno, NV
Country: United States
Start Date: January 9, 2006
End Date: January 12, 2006
Sponsors: American Inst. of Aeronautics and Astronautics
Funding Number(s)
WBS: WBS 984754.02.07.03.22.06
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.