Frozen-Plug Technique for Liquid-Oxygen PlumbingA frozen-plug technique has been conceived as a means of temporarily blocking the flow of liquid oxygen or its vapor through a tube or pipe. The technique makes it possible to perform maintenance, repair, or other work on downstream parts of the cryogenic system in which the oxygen is used, without having to empty an upstream liquid-oxygen reservoir and, hence, without wasting the stored liquid oxygen and without subjecting the reservoir to the stresses of thermal cycling.
Document ID
20110014929
Acquisition Source
Kennedy Space Center
Document Type
Other - NASA Tech Brief
Authors
McCaskey, C. E. "Mac"
(NASA Kennedy Space Center Cocoa Beach, FL, United States)
Lobmeyer, Dennis
(DYNACS Engineering Co., Inc. Cocoa Beach, FL, United States)
Nagy, Zoltan
(DYNACS Engineering Co., Inc. Cocoa Beach, FL, United States)
Peltzer, Rich
(DYNACS Engineering Co., Inc. Cocoa Beach, FL, United States)
Date Acquired
August 25, 2013
Publication Date
June 1, 2005
Publication Information
Publication: NASA Tech Briefs, June 2005
Subject Category
Engineering (General)
Report/Patent Number
KSC-12382
Distribution Limits
Public
Copyright
Public Use Permitted.