NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Phytoplankton-Fluorescence-Lifetime Vertical ProfilerA battery-operated optoelectronic instrument is designed to be lowered into the ocean to measure the intensity and lifetime of fluorescence of chlorophyll A in marine phytoplankton as a function of depth from 0 to 300 m. Fluorescence lifetimes are especially useful as robust measures of photosynthetic productivity of phytoplankton and of physical and chemical mechanisms that affect photosynthesis. The knowledge of photosynthesis in phytoplankton gained by use of this and related instruments is expected to contribute to understanding of global processes that control the time-varying fluxes of carbon and associated biogenic elements in the ocean. The concentration of chlorophyll in the ocean presents a major detection challenge because in order to obtain accurate values of photosynthetic parameters, the intensity of light used to excite fluorescence must be kept very low so as not to disturb the photosynthetic system. Several innovations in fluorometric instrumentation were made in order to make it possible to reach the required low detection limit. These innovations include a highly efficient optical assembly with an integrated flow-through sample interface, and a high-gain, low-noise electronic detection subsystem. The instrument also incorporates means for self-calibration during operation, and electronic hardware and software for control, acquisition and analysis of data, and communications. The electronic circuitry is highly miniaturized and designed to minimize power demand. The instrument is housed in a package that can withstand the water pressure at the maximum depth of 300 m. A light-emitting diode excites fluorescence in the sample flow cell, which is placed at one focal point of an ellipsoidal reflector. A photomultiplier tube is placed at the other focal point. This optical arrangement enables highly efficient collection of fluorescence emitted over all polar directions. Fluorescence lifetime is measured indirectly, by use of a technique based on the same principle as the one described in "Fluorometer for Analysis of Photosynthesis in Phytoplankton" (SSC-00110), NASA Tech Briefs, Vol. 24, No. 1 (November 2000), page 79. The excitation is modulated at a frequency of 70 MHz, and the phase shift between the excitation light and the emitted fluorescence is measured by a detection method in which the 70 MHz signal is down-converted to a 400 Hz signal. The fluorescence lifetime can be computed from the known relationship among the fluorescence lifetime, phase shift, and modulation frequency
Document ID
20110016786
Acquisition Source
Stennis Space Center
Document Type
Other - NASA Tech Brief
Authors
Fernandez, Salvador M.
(Ciencia, Inc. East Hartford, CT, United States)
Guignon, Ernest F.
(Ciencia, Inc. East Hartford, CT, United States)
St. Louis, Ernest
(Ciencia, Inc. East Hartford, CT, United States)
Date Acquired
August 25, 2013
Publication Date
April 1, 2004
Publication Information
Publication: NASA Tech Briefs, April 2004
Subject Category
Man/System Technology And Life Support
Report/Patent Number
SSC-00184-1
Report Number: SSC-00184-1
Distribution Limits
Public
Copyright
Public Use Permitted.
No Preview Available