NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
Comparison of Two Methods for Noninvasive Determination of Stroke Volume During Orthostatic ChallengeBackground: The real time, beat-by-beat, non-invasive determination of stroke volume (SV) is an important parameter in many aerospace related physiologic protocols. In this study, we compared simultaneous estimates of SV calculated from peripheral pulse waveforms with a more conventional non-invasive technique. Methods: Using a prospective, randomized blinded protocol, ten males and nine females completed 12-mm tilt table protocols. The relative change (%(Delta)) in beat-to-beat SV was estimated non-invasively from changes in pulse waveforms measured by application of infrared finger photoplethysmography (IFP) with a Portapres(Registered TradeMark) blood pressure monitoring device and by thoracic impedance cardiography (TIC). The %(Delta) SV values were calculated from continuous SV measurements in the supine posture and over the first 10 s (T1), second 10 s (T2), and 3.5 minutes (T3) of 80deg head-up tilt (HUT). Results: The average %(Delta) SV measured by IFP at T1 (-11.7 +/- 3.7 %) was statistically less (P <0.02) than the average %(Delta) SV measured by TIC at T1 (-21.7 +/- 3.1 %), while the average %(Delta) SV measured by 1FF at T2 (-16.2 +/- 3.9 %) and T3 (-19.1 +/- 3.8 %) were not statistically distinguishable (P > or = 0.322) than the average %(Delta) SV measured by TIC at T2 (-21.8 +/- 2.5 %), and T3 (-22.6 +/- 2.9 %). Correlation coefficients (r(sup 2)) between IFP and TIC were 0.117 (T1), 0.387 (T2), and 0.7 18 (T3). Conclusion: IFP provides beat-to-beat (real time) assessment of %(Delta) SV after 20 sec of transition to an orthostatic challenge that is comparable to the commonly accepted TIC. Our data support the notion that IFP technology which has flown during space missions can be used to accurately assess physiological status and countermeasure effectiveness for orth static problems that may arise in astronauts after space flight. While the peripherally measured IFP response is slightly delayed, the ease of implementing this monitor in the field is advantageous.
Document ID
20110024191
Acquisition Source
Kennedy Space Center
Document Type
Preprint (Draft being sent to journal)
Authors
Doerr, Donald F.
(NASA Kennedy Space Center Cocoa Beach, FL, United States)
Ratliff, Duane A.
(Bionetics Corp. Cocoa Beach, FL, United States)
Sithole, Joseph
(NASA Kennedy Space Center Cocoa Beach, FL, United States)
Convertino, Victor A.
(Army Inst. of Surgical Research Fort Sam Houston, TX, United States)
Date Acquired
August 25, 2013
Publication Date
January 1, 2005
Subject Category
Aerospace Medicine
Report/Patent Number
KSC-2005-082
Report Number: KSC-2005-082
Distribution Limits
Public
Copyright
Public Use Permitted.
No Preview Available