NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
pH Sensitive Microcapsules for Delivery of Corrosion InhibitorsA considerable number of corrosion problems can be solved by coatings. However, even the best protective coatings can fail by allowing the slow diffusion of oxygen and moisture to the metal surface. Corrosion accelerates when a coating delaminates. Often, the problems start when microscopic nicks or pits on the surface develop during manufacturing or through wear and tear. This problem can be solved by the incorporation of a self-healing function into the coating. Several new concepts are currently under development to incorporate this function into a coating. Conductive polymers, nanoparticles, and microcapsules are used to release corrosion-inhibiting ions at a defect site. The objective of this investigation is to develop a smart coating for the early detection and inhibition of corrosion. The dual function of this new smart coating system is performed by pH-triggered release microcapsules. The microcapsules can be used to deliver healing agents to terminate the corrosion process at its early stage or as corrosion indicators by releasing dyes at the localized corrosion sites. The dyes can be color dyes or fluorescent dyes, with or without pH sensitivity. Microcapsules were formed through the interfacial polymerization process. The average size of the microcapsules can be adjusted from 1 to 100 micron by adjusting the emulsion formula and the microcapsule forming conditions. A typical microcapsule size is around 10 microns with a narrow size distribution. The pH sensitivity of the microcapsule can also be controlled by adjusting the emulsion formula and the polymerization reaction time. Both corrosion indicator (pH indicator) and corrosion inhibitor containing microcapsules were formed and incorporated into paint systems. Test panels of selected steels and aluminum alloys were painted using these paints. Testing of compatibility between the microcapsule system and different paint systems are in progress. Initial experiments with the microcapsule containing paint show visible color changes at induced corrosion sites and improvement of corrosion protection. Further investigation of the performance of the coating using electrochemical techniques and long term exposure are currently underway.
Document ID
20120003636
Acquisition Source
Kennedy Space Center
Document Type
Presentation
Authors
Li, Wenyan
Calle, Luz M.
(NASA Kennedy Space Center Cocoa Beach, FL, United States)
Date Acquired
August 25, 2013
Publication Date
October 29, 2006
Subject Category
Structural Mechanics
Report/Patent Number
KSC-2006-118
Report Number: KSC-2006-118
Meeting Information
Meeting: 210th Meeting of The Electrochemical Society
Location: Cancun
Country: Mexico
Start Date: October 29, 2006
End Date: November 3, 2006
Sponsors: Electrochemical Society, Inc.
Distribution Limits
Public
Copyright
Public Use Permitted.
No Preview Available