NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Liquid Hydrogen Propellant Tank Sub-Surface Pressurization with Gaseous HeliumA series of tests were conducted to evaluate the performance of a propellant tank pressurization system with the pressurant diffuser intentionally submerged beneath the surface of the liquid. Propellant tanks and pressurization systems are typically designed with the diffuser positioned to apply pressurant gas directly into the tank ullage space when the liquid propellant is settled. Space vehicles, and potentially propellant depots, may need to conduct tank pressurization operations in micro‐gravity environments where the exact location of the liquid relative to the diffuser is not well understood. If the diffuser is positioned to supply pressurant gas directly to the tank ullage space when the propellant is settled, then it may become partially or completely submerged when the liquid becomes unsettled in a microgravity environment. In such case, the pressurization system performance will be adversely affected requiring additional pressurant mass and longer pressurization times. This series of tests compares and evaluates pressurization system performance using the conventional method of supplying pressurant gas directly to the propellant tank ullage, and then supplying pressurant gas beneath the liquid surface. The pressurization tests were conducted on the Engineering Development Unit (EDU) located at Test Stand 300 at NASA Marshall Space Flight Center (MSFC). EDU is a ground based Cryogenic Fluid Management (CFM) test article supported by Glenn Research Center (GRC) and MSFC. A 150 ft3 propellant tank was filled with liquid hydrogen (LH2). The pressurization system used regulated ambient helium (GHe) as a pressurant, a variable position valve to maintain flow rate, and two identical independent pressurant diffusers. The ullage diffuser was located in the forward end of the tank and was completely exposed to the tank ullage. The submerged diffuser was located in the aft end of the tank and was completely submerged when the tank liquid level was 10% or greater. The ullage diffuser tests were conducted as a baseline to evaluate the performance of the pressurization system, and the submerged diffuser tests showed how the performance of the pressurization system was compromised when the diffuser was submerged in LH2. The test results are evaluated and compared, and included in this report for various propellant tank fill levels.
Document ID
20150016269
Acquisition Source
Marshall Space Flight Center
Document Type
Abstract
Authors
Stephens, J. R.
(NASA Marshall Space Flight Center Huntsville, AL, United States)
Cartagena, W.
(NASA Marshall Space Flight Center Huntsville, AL, United States)
Date Acquired
August 21, 2015
Publication Date
June 24, 2015
Subject Category
Spacecraft Propulsion And Power
Report/Patent Number
M15-4383
Report Number: M15-4383
Meeting Information
Meeting: Space Cryogenics Workshop
Location: Phoenix, AZ
Country: United States
Start Date: June 24, 2015
End Date: June 26, 2015
Sponsors: NASA Glenn Research Center, Cryogenic Society of America, Inc.
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available