Hexavalent Chrome Free Coatings for Electronics Electromagnetic Interference (EMI) Shielding Effectiveness (SE) Interim Test ReportTest specimen configuration was provided by Parker Chomerics. The EMI gasket used in this project was Cho-Seal 6503E. Black oxide alloy steel socket head bolts were used to hold the plates together. Non-conductive spacers were used to control the amount of compression on the gaskets. The following test fixture specifications were provided by Parker Chomerics. The CHO‐TP09 test plate sets selected for this project consist of two aluminum plates manufactured to the specifications detailed in CHO‐TP09. The first plate, referred to as the test frame, is illustrated in Figure 1. The test frame is designed with a cutout in the center and two alternating bolt patterns. One pattern is used to bolt the test frame to the corresponding test cover plate (Figure 2), forming a test plate set. The second pattern accepts the hardware used to mount the fully assembled test plate set to the main adapter plate (Figure 3).
Document ID
20160001424
Acquisition Source
Kennedy Space Center
Document Type
Other
Authors
Kessel, Kurt R. (International Trade Bridge, Inc. Cocoa Beach, FL, United States)
Date Acquired
February 2, 2016
Publication Date
June 1, 2015
Subject Category
Communications And RadarMetals And Metallic Materials