Injection Seeded Laser for Formaldehyde Differential Fluorescence LidarWe describe the design and development of an injection seeded Nd:YVO4 laser for use in a differential fluorescence lidar for measuring atmospheric formaldehyde profiles. A high repetition rate Q-switched laser is modified to accept injection seed input to spectrally narrow and tune the output. The third harmonic output is used to excite formaldehyde (HCHO) fluorescence when tuned to a HCHO absorption line. Spectral confirmation is made with the use of a photoacoustic cell and grating spectrometer.
Document ID
20170003575
Acquisition Source
Goddard Space Flight Center
Document Type
Conference Paper
Authors
Schwemmer, G.
(Science and Engineering Services, Inc. Columbia, MD, United States)
Yakshin, M.
(Science and Engineering Services, Inc. Columbia, MD, United States)
Prasad, C.
(Science and Engineering Services, Inc. Columbia, MD, United States)
Hanisco, T.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Mylapore, A. R.
(MassTech, Inc. Columbia, MD, United States)
Hwang, I. H.
(Science and Engineering Services, Inc. Columbia, MD, United States)
Lee, S.
(Science and Engineering Services, Inc. Columbia, MD, United States)
Date Acquired
April 17, 2017
Publication Date
June 7, 2016
Publication Information
Publication: EPJ Web of Conferences
Publisher: EDP Sciences
Volume: 119
e-ISSN: 2100-014X
Subject Category
Geosciences (General)
Report/Patent Number
GSFC-E-DAA-TN41638
E-ISSN: 2100-014X
Report Number: GSFC-E-DAA-TN41638
Meeting Information
Meeting: International Laser Radar Conference (ILRC 27)
Location: New York, NY
Country: United States
Start Date: July 5, 2015
End Date: July 10, 2015
Sponsors: National Oceanic and Atmospheric Administration
Distribution Limits
Public
Copyright
Public Use Permitted.
Keywords
formaldehyde (HCHO) fluorescence