NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Performance of an X-Ray Microcalorimeter with a 240 Micron Absorber and a 50 Micron TES BilayerWe have been developing superconducting transition-edge sensor (TES) microcalorimeters for a variety of potential astrophysics missions, including Athena. The X-ray Integral Field Unit (X-IFU) instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. The traditional approach within our group has been to use square TES bilayers on molybdenum and gold that are between 100 and 140 microns in size, deposited on silicon nitride membranes to provide a weak thermal conductance to a 50 mK heat bath temperature. It has been shown that normal metal stripes on top of the bilayer are needed to keep the unexplained noise at a level consistent with the expected based upon estimates for the non-equilibrium non-linear Johnson noise.In this work we describe a new approach in which we use a square TES bilayer that is 50 microns in size. While the weak link effect is much stronger in this size of TES, we have found that excellent spectral performance can be achieved without the need for any normal metal strips on top of the TES. A spectral performance of 1.58 eV at 6 KeV has been achieved, the best resolution seen in any of our devices with this pixel size. The absence of normal metal stripes has led to more uniform transition shapes, and more reliable excellent spectral performance. The smaller TES size has meant that that the thermal conductance to the heat bath, determined by the perimeter length of the TES and the membrane thickness, is lower than on previous devices, and thus has a lower count rate capability. This is an advantage for low count-rate applications where the slower speed enables easier multiplexing in the read-out, thus potential higher multiplexing factors. In order to recover the higher count rate capabilities, a potential path exits using thicker silicon nitride membranes to increase the thermal conductance to the heat bath.
Document ID
20170007794
Acquisition Source
Goddard Space Flight Center
Document Type
Presentation
Authors
Miniussi, Antoine R.
(Maryland Univ. Baltimore County Baltimore, MD, United States)
Adams, Joseph S.
(Maryland Univ. Baltimore County Baltimore, MD, United States)
Bandler, Simon R.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Chervenak, James A.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Datesman, Aaron M.
(SGT, Inc. Greenbelt, MD, United States)
Eckart, Megan E.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Ewin, Audrey J.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Finkbeiner, Fred M.
(SGT, Inc. Greenbelt, MD, United States)
Kelley, Richard L.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Kilbourne, Caroline A.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Porter, Frederick S.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Sadleir, John E.
(NASA Goddard Space Flight Center Greenbelt, MD United States)
Sakai, Kazuhiro
(Maryland Univ. Baltimore County Baltimore, MD, United States)
Smith, Stephen J.
(Maryland Univ. Baltimore County Baltimore, MD, United States)
Wakeham, Nicholas A.
(Universities Space Research Association Greenbelt, MD, United States)
Wassell, Edward J.
(SGT, Inc. Greenbelt, MD, United States)
Yoon, Wonsik
(Universities Space Research Association Greenbelt, MD, United States)
Date Acquired
August 17, 2017
Publication Date
July 17, 2017
Subject Category
Astrophysics
Report/Patent Number
GSFC-E-DAA-TN45705
Meeting Information
Meeting: International Workshop on Low Temperature Detectors (LTD 17)
Location: Fukuoka
Country: Japan
Start Date: July 17, 2017
End Date: July 21, 2017
Sponsors: Kurume Univ.
Funding Number(s)
CONTRACT_GRANT: NNG17PT01A
CONTRACT_GRANT: NNG17PT01A
CONTRACT_GRANT: NNG13CR48C
Distribution Limits
Public
Copyright
Public Use Permitted.
No Preview Available