CFD Evaluation of a 3rd Generation LDI CombustorAn effort was undertaken to perform CFD analysis of fluid flow in Lean-Direct Injection (LDI) combustors with axial swirl-venturi elements for next-generation LDI-3 combustor design. The National Combustion Code (NCC) was used to perform non-reacting and two-phase reacting flow computations for a nineteen-element injector array arranged in a three-module, 7-5-7 element configuration. All computations were performed with a consistent approach of mesh-optimization, spray-modeling, ignition and kinetics-modeling with the NCC. Computational predictions of the aerodynamics of the injector were used to arrive at an optimal injector design that meets effective area and fuel-air mixing criteria. LDI-3 emissions (EINOx, EICO and UHC) were compared with the previous generation LDI-2 combustor experimental data at representative engine cycle conditions.
Document ID
20170007985
Acquisition Source
Glenn Research Center
Document Type
Conference Paper
Authors
Ajmani, Kumud (Vantage Partners, LLC Cleveland, OH, United States)
Mongia, Hukam (Purdue Univ. West Lafayette, IN, United States)
Lee, Phil (Woodward FST, Inc. Zeeland, MI, United States)
Date Acquired
August 24, 2017
Publication Date
July 10, 2017
Subject Category
Fluid Mechanics And Thermodynamics
Report/Patent Number
GRC-E-DAA-TN43533Report Number: GRC-E-DAA-TN43533
Meeting Information
Meeting: AIAA Propulsion & Energy 2017
Location: Atlanta, GA
Country: United States
Start Date: July 10, 2017
End Date: July 12, 2017
Sponsors: American Inst. of Aeronautics and Astronautics