FLEET Velocimetry in the Common Research Model’s Wing WakeFemtosecond laser electronic excitation tagging was used to make velocity measurements in the wake of the wing of the Common Research Model (CRM). Experiments were performed in the NASA Langley Research Center’s National Transonic Facility over a range of tunnel operating conditions. Pressures ranged from 205 to 411 kPa, temperatures from 278 to 323 K, and Mach from 0.1 to 0.9. Velocity was also determined over a range of model angles of attack. Time-averaged velocity results were obtained in both air and nitrogen, while single-shot velocity was obtained under certain tunnel operating conditions. Spatially-resolved, two dimensional, single component velocity measurements were achieved using a newly-developed laser scanning technique, which proved sufficiently sensitive to measure an approximately 5% velocity deficit in the wing wake region of the CRM.
Document ID
20200002934
Acquisition Source
Langley Research Center
Document Type
Conference Paper
Authors
Daniel T Reese (Langley Research Center Hampton, Virginia, United States)
Paul M Danehy (Langley Research Center Hampton, Virginia, United States)
Eric L Walker (Langley Research Center Hampton, Virginia, United States)
S Melissa Rivers (Langley Research Center Hampton, Virginia, United States)
William K Goad (Jacobs (United States) Dallas, Texas, United States)
Date Acquired
April 22, 2020
Publication Date
January 6, 2020
Publication Information
Publisher: American Institute of Aeronautics and Astronautics