Avalanche ASV016204 (Pre-Production Samples) 40nm MRAM Total Ionizing Dose Test ReportThe purpose of this test was to characterize the Avalanche Technology ASV016204’s total dose response. In the test, the device was exposed to high dose rate (HDR) irradiations using gamma radiation. Device functionality (in terms of memory cell upsets and read/write ability) as well as power supply currents during various modes of operations were recorded.
Document ID
20205000788
Acquisition Source
Goddard Space Flight Center
Document Type
Other - Test report for upload to public website.
Authors
Ted Wilcox
(Goddard Space Flight Center Greenbelt, Maryland, United States)
Date Acquired
April 13, 2020
Publication Date
May 31, 2020
Publication Information
Subject Category
Space Radiation
Funding Number(s)
OTHER: 2020-561-NEPP
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
Technical Review
Single Expert
Keywords
Total Ionizing Dose (TID)
radiation testing
high dose rate (HDR)
No Preview Available