NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
HSYE-117RH Voltage Linear Regulator Total Ionizing Dose Test ReportThe purpose of this test was to validate the Intersil HSYE-117RH-Q flight lot for use in the fabrication of Europa Clipper Propulsion subsystem flight hardware. This test shall serve as the radiation lot acceptance test (RLAT) for the flight lot date with wafer lot number G3X3CQC and lot date code (LDC) 1830. Low dose rate (LDR) irradiations have been performed by the manufacturer, but only to 100 krad(Si). This test determined the enhanced low dose rate sensitivity (ELDRS) of the device up to the mission specific dose of 125 krad(Si).
Document ID
20205004068
Acquisition Source
Goddard Space Flight Center
Document Type
Other - Test Report
Authors
Megan Casey
(Goddard Space Flight Center Greenbelt, Maryland, United States)
Anthony Phan
(Science Systems and Applications (United States) Lanham, Maryland, United States)
Alyson Topper
(Science Systems and Applications (United States) Lanham, Maryland, United States)
Date Acquired
July 1, 2020
Publication Date
August 1, 2020
Publication Information
Subject Category
Spacecraft Instrumentation And Astrionics
Funding Number(s)
PROJECT: Europa Clipper Program
CONTRACT_GRANT: 80GSFC18C0120
Distribution Limits
Public
Copyright
Public Use Permitted.
Technical Review
Single Expert
Keywords
Total Ionizing Dose (TID)
Intersil HSYE-117RH-Q
Low dose rate (LDR)
Enhanced Low Dose Rate Sensitivity (ELDRS)
No Preview Available