NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Press Enter or click the Search button to begin your search.

Back to Results
A mechanically pumped two-phase fluid loop for thermal control based on the capillary pumped loopA novel two-phase Mechanically Pumped Fluid Loop (MPFL) for thermal control is presented. The operating principles are outlined and results from a prototype test facility are shown. The system is a variant of the Capillary Pumped Loop (CPL) where a mechanical pump and bypass line have been added to make a pump-assisted CPL. The benefits of this design are discussed, and test results are shown that demonstrate the feasibility of the system architecture. Stable performance for heat loads between 30 W and 850 W are reported along with the capability of handling a heat flux of up to 13 W/cm2. In addition, the testbed incorporates a novel planar Additively Manufactured (AM) evaporator. Preliminary test results show that the evaporator can maintain isothermality within 0.5 C for heat loads up to
100 W and within 3 C for heat loads up to 325 W.
Document ID
20210012284
Acquisition Source
Jet Propulsion Laboratory
Document Type
Preprint (Draft being sent to journal)
External Source(s)
Authors
Sunada, Eric
Daimaru, Takuro
Cappucci, Stefano
Furst, Benjamin
Date Acquired
July 7, 2019
Publication Date
July 7, 2019
Publication Information
Publisher: Pasadena, CA: Jet Propulsion Laboratory, National Aeronautics and Space Administration, 2019
Distribution Limits
Public
Copyright
Other
Technical Review

Available Downloads

There are no available downloads for this record.
No Preview Available