NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Application of Radon Transform to Multi-Angle Measurements Made by the Research Scanning Polarimeter: A New Approach to Cloud Tomography. Part I: Theory and Tests on Simulated Data. The Research Scanning Polarimeter (RSP) is an airborne along-track scanner measuring the polarized and total reflectances in 9 spectral channels. The RSP was a prototype for the Aerosol Polarimetry Sensor (APS) launched on-board the NASA Glory satellite. Currently the retrieval algorithms developed for the RSP are being adopted for the measurements of the space-borne polarimeters on the upcoming NASA’s Plankton, Aerosol, Cloud Ocean Ecosystem (PACE)satellite mission. The RSP’s uniquely high angular resolution coupled with the high frequency of measurements allows for characterization of liquid water cloud droplet sizes using the polarized rainbow structure. It also provides geometric constraints on the cumulus cloud’s 2D cross section yielding the cloud’s geometric shape estimates. In this study we further build on the latter technique to develop a new tomographic approach to retrieval of cloud internal structure from remote sensing measurements. While tomography in the strict definition is a technique based on active measurements yielding a tomogram (directional optical thickness as a function of angle and offset of the view ray), we developed a “semi-tomographic” approach in which tomogram of the cloud is estimated from passive observations instead of being measured directly. This tomogram is then converted into 2D spatial distribution of the extinction coefficient using inverse Radon transform (filtered back projection) which is the standard tomographic procedure used e.g., in medical CT scans. This algorithm is computationally inexpensive compared to techniques relying on highly-multi-dimensional least-square fitting; it does not require iterative 3D RT simulations. The resulting extinction distribution is defined up to an unknown constant factor, so we discuss the ways to calibrate it using additional independent measurements. In the next step we use the profile of the droplet size distribution parameters from the cloud’s side (derived by fitting the polarized rainbows) to convert the 2D extinction distribution into that of the droplet number concentration. We illustrate and validate the proposed technique using 3D-RT-simulatedRSP observations of a LES-generated Cu cloud. Quantitative comparisons between the retrieved and the original optical and microphysical parameters are presented.
Document ID
20210025093
Acquisition Source
Goddard Space Flight Center
Document Type
Accepted Manuscript (Version with final changes)
Authors
Mikhail D Alexandrov
(Columbia University New York, New York, United States)
Claudia Emde
(Ludwig Maximilian University of Munich Munich, Germany)
Bastiaan Van Diedenhoven
(Netherlands Institute for Space Research Utrecht, Netherlands)
Brian Cairns
(Goddard Institute for Space Studies New York, New York, United States)
Date Acquired
November 29, 2021
Publication Date
November 22, 2021
Publication Information
Publication: Frontiers in Remote Sensing
Publisher: Frontiers
Volume: 2
Issue Publication Date: January 1, 2021
ISSN: 2673-6187
Subject Category
Meteorology And Climatology
Funding Number(s)
CONTRACT_GRANT: NNH16ZDA001N-CAMP2EX
Distribution Limits
Public
Copyright
Portions of document may include copyright protected material.
Technical Review
Professional Review
Keywords
clouds
tomography
Radon Transform
research scanning polarimeter
reflectance
airborne remote sensing
No Preview Available