Linear Technology LTC2054HVMP Operational Amplifier Low Dose Rate Total Ionizing Dose Test ReportThe purpose of this test was to characterize the LTC2054HVMPS5 (LTC2054) parameter degradation for total ionizing dose (TID) response. In the test, the device was exposed to low dose rate (LDR) irradiations using gamma radiation to account for the effects of enhanced low dose rate sensitivity (ELDRS) on the bipolar device.