NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Lifetime estimates for sterilizable silver-zinc battery separatorsThe lifetime of separator membranes currently employed in the electrolyte environment of silver-zinc batteries was estimated at 3 to 5 years. The separator membranes are crosslinked polyethylene film containing grafted poly (potassium acrylate)(PKA), the latter being the hydrophilic agent which promotes electrolyte ion transport. The lifetime was estimated by monitoring the rate of loss of PKA from the separators, caused by chemical attack of the electrolyte, and relating this loss rate to a known relationship between battery performance and PKA concentration in the separators.
Document ID
19720021298
Document Type
Other
Authors
Cuddihy, E. F. (Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Walmsley, D. E. (Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Moacanin, J. (Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Date Acquired
August 6, 2013
Publication Date
April 1, 1972
Publication Information
Publication: JPL Quarterly Tech. Rev., Vol. 2, No. 1
Subject Category
AUXILIARY SYSTEMS
Distribution Limits
Public
Copyright
Public Use Permitted.

Related Records

IDRelationTitle19720021291Analytic PrimaryJPL Quarterly Technical Review, Volume 2, No. 1, April 1972N72-28941 19-34Analytic Primary