Flow interference in a variable porosity trisonic wind tunnel.Pressure data from a 20-degree cone-cylinder in a variable porosity wind tunnel for the Mach range 0.2 to 5.0 are compared to an interference free standard in order to determine wall interference effects. Four 20-degree cone-cylinder models representing an approximate range of percent blockage from one to six were compared to curve-fits of the interference free standard at each Mach number and errors determined at each pressure tap location. The average of the absolute values of the percent error over the length of the model was determined and used as the criterion for evaluating model blockage interference effects. The results are presented in the form of the percent error as a function of model blockage and Mach number.
Document ID
19720057926
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Davis, J. W. (NASA Marshall Space Flight Center Gas Dynamics Section, Huntsville, Ala., United States)
Graham, R. F. (Northrop Services, Inc. Huntsville, Ala., United States)