Flight test results for the F-8 digital fly-by-wire aircraft control sensor analytic redundancy management techniqueThis paper reviews the formulation and flight test results of an algorithm to detect and isolate the first failure of any one of twelve duplex control sensor signals being monitored. The technique uses like-signal differences for fault detection while relying upon analytic redundancy relationships among unlike quantities to isolate the faulty sensor. The fault isolation logic utilizes the modified sequential probability ratio test, which explicitly accommodates the inevitable irreducible low frequency errors present in the analytic redundancy residuals. In addition, the algorithm uses sensor output selftest, which takes advantage of the duplex sensor structure by immediately removing a highly erratic sensor from control calculations and analytic redundancy relationships while awaiting a definitive fault isolation decision via analytic redundancy. This study represents a proof of concept demonstration of a methodology that can be applied to duplex or higher flight control sensor configurations and, in addition, can monitor the health of one simplex signal per analytic redundancy relationship.
Document ID
19810059731
Acquisition Source
Legacy CDMS
Document Type
Conference Proceedings
Authors
Deckert, J. C. (Charles Stark Draper Laboratory, Inc. Cambridge, MA, United States)