Ion extraction capabilities of closely spaced gridsThe ion extraction capabilities of accelerator systems with small screen hole diameters (less than 2.0 mm) are investigated at net-accelerating voltages of 100, 300, and 500 V. Results show that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 1.0 mm, but impingement-limited performance was found to be dependent on the grid separation distance, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained using small hole diameters and closely spaced grids indicate a new mode of grid operation where high current density operation can be achieved with a specified net acceleration voltage by operating the grids at a high rather than low net-to-total acceleration voltage. Beam current densities as high as 25 mA/sq cm were obtained using grids with 1.0 mm diameter holes operating at a net accelerating voltage of 500 V.
Document ID
19830031333
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Rovang, D. C. (Colorado State Univ. Fort Collins, CO, United States)
Wilbur, P. J. (Colorado State University Fort Collins, CO, United States)
Date Acquired
August 11, 2013
Publication Date
November 1, 1982
Subject Category
Spacecraft Propulsion And Power
Report/Patent Number
AIAA PAPER 82-1894
Meeting Information
Meeting: Japan Society for Aeronautical and Space Sciences, and DGLR, International Electric Propulsion Conference