NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Line strength measurements using diode lasers - The nu2 band of H2SThe strengths of 94 lines in the nu2 band of H2S have been measured with an average accuracy of 3 percent using a tunable diode laser. The line strengths are determined from the peak absorption of nearly Doppler-shaped lines. A detailed error analysis of this measurement method is given. Ratios of the measured line strengths to strengths calculated assuming no vibration-rotation interactions are shown to range from as low as 0.057 to as high as 4.71.
Document ID
19830057964
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Strow, L. L.
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
August 11, 2013
Publication Date
May 1, 1983
Publication Information
Publication: Journal of Quantitative Spectroscopy and Radiative Transfer
Volume: 29
ISSN: 0022-4073
Subject Category
Atomic And Molecular Physics
Accession Number
83A39182
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available