High voltage battery cell scanner developmentBattery cell voltage scanners have been previously used in low voltage spacecraft applications. In connection with future missions involving an employment of high-power high voltage power subsystems and/or autonomous power subsystem management for unattended operation, it will be necessary to utilize battery cell voltage scanners to provide battery cell voltage information for early detection of impending battery cell degradation/failures. In preparation for such missions, a novel battery cell voltage scanner design has been developed. The novel design makes use of low voltage circuit modules which can be applied to high voltage batteries in a building block fashion. A description is presented of the design concept and test results of the high voltage battery cell scanner, and its operation with an autonomously managed power subsystem is discussed.
Document ID
19840047347
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Lepisto, J. W.
(TRW Space Technology Labs. Redondo Beach, CA, United States)
Decker, D. K.
(TRW, Inc. Space and Technology Group, Redondo Beach, CA, United States)
Graves, J.
(NASA Marshall Space Flight Center Huntsville, AL, United States)
Date Acquired
August 12, 2013
Publication Date
January 1, 1983
Subject Category
Spacecraft Propulsion And Power
Accession Number
84A30134
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.