The NASA Langley 0.3-m transonic cryogenic tunnelThe Langley 0.3-m Transonic Cryogenic Tunnel (0.3-m TCT) can operate from ambient to cryogenic temperatures at absolute pressures from 1 to 6 bars. Since the 0.3-m TCT began operation in 1973, it has been used to develop instrumentation and operating techniques for cryogenic tunnels as well as for aerodynamic tests where advantage can be taken of the extremely wide range of Reynolds number available. This paper describes the present capabilities of the 0.3-m TCT and gives an overview of recent research activities which include both steady and unsteady testing. Emphasis is given to safety and the development of testing techniques for cryogenic tunnels. Results of studies aimed at establishing the lower limits of operating temperature are presented and the impact of these studies on tunnel operation is discussed. Finally, the design features and operating characteristics of a new self-streamlining wall test section recently installed in the tunnel circuit are described.
Document ID
19860010957
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Kilgore, R. A. (NASA Langley Research Center Hampton, VA, United States)
Date Acquired
August 12, 2013
Publication Date
July 1, 1985
Publication Information
Publication: AGARD Special Course on Cryogenic Technology for Wind Tunnel Testing