Spray drop size and velocity measurements using the Phase/Doppler Particle AnalyzerDetailed measurements of the drop size and velocity distributions were obtained for a swirl chamber pressure atomizer. These data were obtained with the Phase/Doppler Particle Analyzer manufactured by Aerometrics, Inc. Direct measurements of the size distributions revealed the evolving characteristics of the spray. Size velocity correlations were used to evaluate the effect of velocity relaxation on the size distributions. The simultaneous measurement of drop size and velocity was of major importance in accurately describing the changes in the local drop size distributions and mass flux.