Transient analysis of chilldown in a cryogenic transfer lineA numerical model was developed, with the SINDA'85/FLUINT program, for calculating the thermal and hydrodynamic transients that occur during the chilldown of a cryogenic transfer line, using a well documented test case to validate the modeling process. Using this model, a total of ten cases were analyzed to evaluate the effects of variable inlet valve position, inlet pressures, and the use of an internal flow liner to promote nucleate boiling. It was found that an efficient transfer line cooldown can be achieved if the inlet flow is throttled, to reduce the flow rate and quality, and an internal flow liner such as Teflon is used.