Predicted and preliminary evaluation of the X-ray performance of the AXAF Technology Mirror AssemblyThe fabrication of the Technology Mirror Assembly (TMA) is complete, and performance predictions were made based upon mechanical and visible light measurements of the surface properties. An X-ray calibration program has been executed, and a preliminary analysis of a portion of the data is presented. The X-ray image distribution results are in reasonable agreement with the performance predictions which were calculated prior the start of the X-ray tests. The measured X-ray imaging performance approaches that expected for the Advanced X-ray Astrophysics Facility (AXAF).