Thermal/structural analysis of a transpiration cooled nozzleThe 8-foot High Temperature Tunnel (HTT) at LaRC is a combustion driven, high enthalpy blow down wind tunnel. In Mar. 1991, during check out of the transpiration cooled nozzle, pieces of platelets were found in the tunnel test section. It was determined that incorrect tolerancing between the platelets and the housing was the primary cause of the platelet failure. An analysis was performed to determine the tolerance layout between the platelets and the housing to meet the structural and performance criteria under a range of thermal, pressure, and bolt preload conditions. Three recommendations resulted as a product of this analysis.
Document ID
19920009635
Acquisition Source
Legacy CDMS
Document Type
Technical Memorandum (TM)
Authors
Gregory, Peyton B.
(NASA Langley Research Center Hampton, VA, United States)
Thompson, Jon E.
(NASA Langley Research Center Hampton, VA, United States)
Babcock, Dale A.
(NASA Langley Research Center Hampton, VA, United States)
Gray, Carl E., Jr.
(NASA Langley Research Center Hampton, VA, United States)
Mouring, Chris A.
(NASA Langley Research Center Hampton, VA, United States)
Date Acquired
September 6, 2013
Publication Date
February 1, 1992
Subject Category
Structural Mechanics
Report/Patent Number
NASA-TM-104184
NAS 1.15:104184
Accession Number
92N18877
Funding Number(s)
PROJECT: RTOP 505-80-31-01
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available