NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Hydrogen no-vent testing in a 5 cubic foot (142 liter) tank using spray nozzle and spray bar liquid injectionA total of 38 hydrogen no-vent fill tests were performed in this test series using various size spray nozzles and a spray bar with different hole sizes in a 5 cubic foot receiver tank. Fill levels of 90 percent by volume or greater were achieved in 26 of the tests while maintaining a receiver tank pressure below 30 psia. Spray nozzles were mounted at the top of the tank, whereas, the spray bar was centered in the tank axially. The spray nozzle no-vent fills demonstrated tank pressure and temperature responses comparable to previous test series. Receiver tank pressure responses for the spray bar configuration were similar to the spray nozzle tests with the pressure initially rising rapidly, then leveling off as vapor condenses onto the discharging liquid streams, and finally ramping up near the end of the test due to ullage compression. Both liquid injection techniques tested were capable of filling the receiver tank to 90 percent under variable test conditions. Comparisons between the spray nozzle and spray bar configurations for well matched test conditions indicate the spray nozzle injection technique is more effective in minimizing the receiving tank pressure throughout a no-vent fill compared to the spray bar under normal gravity conditions.
Document ID
19920066095
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Moran, Matthew E.
(NASA Lewis Research Center Cleveland, OH, United States)
Nyland, Ted W.
(NASA Lewis Research Center Cleveland, OH, United States)
Date Acquired
August 15, 2013
Publication Date
July 1, 1992
Subject Category
Spacecraft Propulsion And Power
Report/Patent Number
AIAA PAPER 92-3063
Accession Number
92A48719
Distribution Limits
Public
Copyright
Other

Available Downloads

There are no available downloads for this record.
No Preview Available