NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Numerical modeling for an electric-field hyperthermia applicatorHyperthermia, in conjunction with radiation and chemotherapy for treatment of cancers, is an area of current concern. Experiments have shown that hyperthermia can increase the potency of many chemotherapy drugs and the effectiveness of radiation for treating cancer. A combination of whole body or regional hyperthermia with chemotherapy or radiation should improve treatment results. Conventional methods for inducing whole body hyperthermia, such as exposing a patient in a radiant cabinet or under a hot water blanket, conduct heat very slowly from the skin to the body core. Thus a more efficient system, such as the three-plate electric-field hyperthermia applicator (EHA), is developed. This three-plate EHA has one top plate over and two lower plates beneath the patient. It is driven at 27.12 MHz with 500 Watts through a matching circuit. Using this applicator, a 50 kg pig was successfully heated to 42 C within 45 minutes. However, phantom and animal studies have indicated non-uniform heating near the side of the body. In addition, changes in the size and distance between the electrode plates can affect the heating (or electromagnetic field) pattern. Therefore, numerical models using the method of moments (MOM) or the finite difference time domain (FDTD) technique are developed to optimize the heating pattern of this EHA before it is used for human trials. The accuracy of the numerical modeling has been achieved by the good agreement between the MOM and FDTD results for the three-plate EHA without a biological body. The versatile FDTD technique is then applied to optimize the EHA design with a human body. Both the numerical and measured data in phantom blocks will be presented. The results of this study will be used to design an optimized system for whole body or regional hyperthermia.
Document ID
19940015978
Acquisition Source
Legacy CDMS
Document Type
Conference Paper
Authors
Wu, Te-Kao
(Jet Propulsion Lab., California Inst. of Tech. Pasadena, CA, United States)
Chou, C. K.
(City of Hope Medical Center Duarte, CA., United States)
Chan, K. W.
(City of Hope Medical Center Duarte, CA., United States)
Mcdougall, J.
(City of Hope Medical Center Duarte, CA., United States)
Date Acquired
September 6, 2013
Publication Date
January 1, 1993
Publication Information
Publication: gress In Electromagnetics Research Symposium (PIERS)
Subject Category
Aerospace Medicine
Accession Number
94N20451
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.
No Preview Available