NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Development of an Automated Reader for Analysis and Storage of Personnel Dosimeter Badge DataThe collection and archiving of data from personnel dosimeters has become increasingly important in light of the lowered threshold limit values (TLV) for hydrazine (HZ), monomethylhydrazine (MMH), and unsymmetrical dimethylhydrazine (UDMH). The American Conference of Government Industrial Hygienists (ACGIH) lowered the TLV from 100 parts per billion (ppb) to 10 ppb and has caused increased concern over long term exposures of personnel to trace levels of these hypergols and other potentially harmful chemicals. An automated system of reading the exposure levels of personnel dosimeters and storing exposure data for subsequent evaluation has been developed. The reading of personnel dosimeter badges for exposure lo potentially harmful vapor concentrations of hydrazines or other chemicals is performed visually by comparing the color developed by the badge with a calibrated color comparator. The result obtained using visual comparisons of the developed badge color with the comparator may vary widely from user to user. The automated badge reader takes the variability out of the dosimeter reading by accurately comparing the reflectance obtained from a colored spot on the badge with a reading on the same spot prior to any exposure to chemical vapors. The observed difference between the reflectance values is used as part of a calculation of the dose value for the badge based on a stored calibration curve. The badge reader also stores bar-code data unique to each badge, as well as bar-code information on the user, as part of the permanent badge record. The start and stop exposure times for each badge are recorded and can be used as part of the calculated concentration, in ppm, for each badge logged during a recording period. The badge reader is equipped with a number of badge holders, each of which is unique to a specific type of personnel dosimeter badge. This gives the reader maximum flexibility to allow for the reading of several different types of badges. Test results of the badge reader for several different types of personnel dosimeter badges are presented within the body of this paper.
Document ID
19970017913
Acquisition Source
Kennedy Space Center
Document Type
Conference Paper
Authors
Meneghelli, B. J.
(I-NET, Inc. Cocoa Beach, FL United States)
Hodge, T. R.
(I-NET, Inc. Cocoa Beach, FL United States)
Robinson, L. J.
(I-NET, Inc. Cocoa Beach, FL United States)
Lueck, D. E.
(NASA Kennedy Space Center Cocoa Beach, FL United States)
Date Acquired
August 17, 2013
Publication Date
March 1, 1997
Publication Information
Publication: The 1997 JANNAF Propellant Development and Characterization Subcommittee and Safety and Environmental Protection Subcomittee Joint Meeting
Volume: 1
Subject Category
Documentation And Information Science
Accession Number
97N20024
Funding Number(s)
CONTRACT_GRANT: NAS10-11943
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.

Available Downloads

There are no available downloads for this record.
No Preview Available