Weld Pool Stability in the Flat PositionThe Soft Plasma Arc (SPA) process was devised to avoid interactions between backshield and full penetration mode plasma jet in welding 2195 aluminum-lithium alloy. Occasional sudden and mysterious losses in penetration were encountered in flat position SPA welding. To understand what was happening a model of the dynamics of the molten metal meniscus at the root of the weld was worked out. When the power input to the weld P(sub in) exceeds the power leakage P(sub out) the difference in power is absorbed by an increase in the molten weld pool volume V, Rho X L(SUB m) X (d(V)/dt)) = P(sub in) - P(sub out) where rho is the density and L(sub m) the specific heat of the weld metal.