NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Free-Roller Versus Fixed-Roller Fixtures in Flexure Testing of Advanced Ceramic MaterialsThe error associated with strength measurements made with fixed-roller and V-grooved roller figures was studied with a variety of roller and figure material combinations. Both the fixed-roller and the V-grooved fixtures yielded an error in stress of about 4 to 7%. They also exhibited an appreciable amount of load strain hysteresis. Dynamic fatigue testing of 96 wt.% alumina verified the error: the fatigue strength was overestimated by 7 to 9% for the fixed roller configuration. The source of error is exclusively attributed to friction between the rollers and the specimen surface, as verified by previous investigators.
Document ID
20010037713
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Salem, Jonathan A.
(NASA Lewis Research Center Cleveland, OH United States)
Choi, Sung R.
(Cleveland State Univ. Cleveland, OH United States)
Date Acquired
August 20, 2013
Publication Date
January 1, 1996
Publication Information
Publication: Ceramic Engineering and Science Proceedings
Publisher: American Ceramic Society
Volume: 17
Subject Category
Nonmetallic Materials
Funding Number(s)
CONTRACT_GRANT: DE-AC05-84OR-21400
Distribution Limits
Public
Copyright
Other

Available Downloads