NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Secondary particle contribution to LET spectra on LDEFFour experiments utilizing passive detectors (P0006, P0004, A0015, M0004) were flown on LDEF to study the radiation environment. These experiments have been summarized in a companion paper (Benton et al., 1996). One of the experimental goals was to measure LET spectra at different locations and shielding depths with plastic nuclear track detectors (PNTD). It was found that the LET spectra extended well above the LET cutoff imposed by the geomagnetic field on GCR particle penetration into LEO. The high LET particles detected were mostly short-range (range < 2000 m), indicating that they were secondaries produced locally within the PNTD. The presence of these high LET particle fluences is important for the determination of dose equivalent because of the high Quality Factors (Q) involved. A relatively small fraction of particle fluence can contribute a large fraction of dose equivalent. Short-range, inelastic secondary particles produced by trapped protons in the South Atlantic Anomaly (SAA) were found to be a major contributor to the LET spectra above 100 keV/micrometer. The LET spectra were found to extend beyond the approximately 137 keV/micrometer relativistic GCR Fe peak to over 1000 keV/micrometer. The high LET tail of the LET spectra was measured in CR-39 and polycarbonate PNTDs using different techniques. GCR made a relatively modest contribution to the LET spectra as compared to the contributions from short-range secondary particles and stopping protons. LET spectra intercomparisons were made between LDEF measurements and exposures to 154 MeV accelerated proton beams. The similarities support the role of nuclear interactions by trapped protons as the major source of secondary particles in the PNTDs. Also techniques were employed to reduce the range cutoff for detection of the short-range secondaries to approximately 1 micrometer, so that essentially all secondary particles were included in the LET spectra. This has allowed a more realistic assessment of secondary contribution to dose equivalent. Comparisons of measured and calculated LET spectra have been made that demonstrate the need for more accurate modeling of secondary particles in radiation transport codes. Comparisons include preliminary calculations in which attempts have been made to include secondary particles.
Document ID
20040089399
Acquisition Source
Marshall Space Flight Center
Document Type
Reprint (Version printed in journal)
Authors
Benton, E. R.
(Eril Research Inc. San Rafael, CA 94915-0788, United States)
Benton, E. V.
Frank, A. L.
Frigo, L. A.
Csige, I.
Date Acquired
August 21, 2013
Publication Date
November 1, 1996
Publication Information
Publication: Radiation measurements
Volume: 26
Issue: 6
ISSN: 1350-4487
Subject Category
Aerospace Medicine
Funding Number(s)
CONTRACT_GRANT: NAG8-168
CONTRACT_GRANT: NAGW-4154
CONTRACT_GRANT: NAG8-282
Distribution Limits
Public
Copyright
Other
Keywords
long duration
LDEF Project
Non-NASA Center
NASA Discipline Radiation Health
Flight Experiment
unmanned

Available Downloads

There are no available downloads for this record.
No Preview Available