Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometryThe performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.
Document ID
20040112239
Acquisition Source
Headquarters
Document Type
Reprint (Version printed in journal)
External Source(s)
Authors
Merritt, D. A.
(Biogeochemical Laboratories, Indiana University Department of Chemistry, Bloomington 47405-1403, United States)
Hayes, J. M.
Date Acquired
August 21, 2013
Publication Date
July 15, 1994
Publication Information
Publication: Analytical chemistry
Volume: 66
Issue: 14
ISSN: 0003-2700
Subject Category
Exobiology
Funding Number(s)
CONTRACT_GRANT: NAGW-1940
Distribution Limits
Public
Copyright
Other
Keywords
NASA Discipline Exobiology
Non-NASA Center

Available Downloads

There are no available downloads for this record.
No Preview Available