NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Left ventricular diastolic filling with an implantable ventricular assist device: beat to beat variability with overall improvementOBJECTIVES: We studied the effects of left ventricular (LV) unloading by an implantable ventricular assist device on LV diastolic filling. BACKGROUND: Although many investigators have reported reliable systemic and peripheral circulatory support with implantable LV assist devices, little is known about their effect on cardiac performance. METHODS: Peak velocities of early diastolic filling, late diastolic filling, late to early filling ratio, deceleration time of early filling, diastolic filling period and atrial filling fraction were measured by intraoperative transesophageal Doppler echocardiography before and after insertion of an LV assist device in eight patients. A numerical model was developed to simulate this situation. RESULTS: Before device insertion, all patients showed either a restrictive or a monophasic transmitral flow pattern. After device insertion, transmitral flow showed rapid beat to beat variation in each patient, from abnormal relaxation to restrictive patterns. However, when the average values obtained from 10 consecutive beats were considered, overall filling was significantly normalized from baseline, with early filling velocity falling from 87 +/- 31 to 64 +/- 26 cm/s (p < 0.01) and late filling velocity rising from 8 +/- 11 to 32 +/- 23 cm/s (p < 0.05), resulting in an increase in the late to early filling ratio from 0.13 +/- 0.18 to 0.59 +/- 0.38 (p < 0.01) and a rise in the atrial filling fraction from 8 +/- 10% to 26 +/- 17% (p < 0.01). The deceleration time (from 112 +/- 40 to 160 +/- 44 ms, p < 0.05) and the filling period corrected by the RR interval (from 39 +/- 8% to 54 +/- 10%, p < 0.005) were also significantly prolonged. In the computer model, asynchronous LV assistance produced significant beat to beat variation in filling indexes, but overall a normalization of deceleration time as well as other variables. CONCLUSIONS: With LV assistance, transmitral flow showed rapidly varying patterns beat by beat in each patient, but overall diastolic filling tended to normalize with an increase of atrial contribution to the filling. Because of the variable nature of the transmitral flow pattern with the assist device, the timing of the device cycle must be considered when inferring diastolic function from transmitral flow pattern.
Document ID
20040172871
Acquisition Source
Legacy CDMS
Document Type
Reprint (Version printed in journal)
Authors
Nakatani, S.
(Cleveland Clinic Foundation Ohio 44195, United States)
Thomas, J. D.
Vandervoort, P. M.
Zhou, J.
Greenberg, N. L.
Savage, R. M.
McCarthy, P. M.
Date Acquired
August 22, 2013
Publication Date
November 1, 1997
Publication Information
Publication: Journal of the American College of Cardiology
Volume: 30
Issue: 5
ISSN: 0735-1097
Subject Category
Life Sciences (General)
Funding Number(s)
CONTRACT_GRANT: R01HL56688
Distribution Limits
Public
Copyright
Other
Keywords
Non-NASA Center
NASA Discipline Cardiopulmonary

Available Downloads

There are no available downloads for this record.
No Preview Available