NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
Launch Complex 39A, SWMU 008, Operations, Maintenance, and Monitoring Report, Kennedy Space Center, FLThis Operations, Maintenance, and Monitoring Report (OMMR) presents the findings, observations, and results from Year 1 operation of the air sparging (AS) groundwater interim measure (IM) for High-Concentration Plumes (HCPs) and Low-Concentration Plumes (LCPs) within the perimeter fence line at Launch Complex 39A (LC39A) located at Kennedy Space Center (KSC), Florida. The objective of the LC39A groundwater IM is to actively decrease concentrations of trichloroethene (TCE), cis-1,2-dichloroethene (cDCE), and vinyl chloride (VC) in groundwater in the HCP and LCP within the pad perimeter fence line via AS to levels less than Florida Department of Environmental Protection (FDEP) Groundwater Cleanup Target Levels (GCTLs). The objective was developed because LC39A is currently being leased to Space Exploration Technologies (SpaceX), and the original IM for monitored natural attenuation (MNA) over an extended period of time was not suitable for future planned site use.
Document ID
20160006339
Acquisition Source
Kennedy Space Center
Document Type
Other
Authors
Wilson, Deborah M.
(Tetra Tech, Inc. Kennedy Space Center, FL, United States)
Date Acquired
May 17, 2016
Publication Date
April 1, 2016
Subject Category
Ground Support Systems And Facilities (Space)
Environment Pollution
Report/Patent Number
KSC-E-DAA-TN31774
Funding Number(s)
CONTRACT_GRANT: NNK12CA15B
Distribution Limits
Public
Copyright
Public Use Permitted.
Keywords
Operations
Launch Complex 39A
Monitoring
SWMU 008
Maintenance
No Preview Available