A Method for Removal of Bakelite-Impregnated Wire Strain GagesAn increasing interest is being shown in the use of wire-type strain gages to measure static and dynamic stresses in aircraft-engine parts. Bakelite cement has been found satisfactory as a bonding agent for attaching the strain gages to machine parts that must operate at elevated temperatures. On many occasions, it is desired to remove Bakelite-cemented gages from the test parts for the purpose of replacing faulty gages or of returning the parts to service after strain measurements have been completed. Removal of the gages by means of scraping without prior treatment is very unsatisfactory because it is tedious and almost invariably damages the finished surface. Various solvents have been tried, but all attempts in this direction have been unsuccessful inasmuch as Bakelite cement, when properly baked, forms a polymer of very high molecular weight that resists the action of solvents. This report presents a gas-flame method of removal that is rapid and does not inure the structural part.
Document ID
20160011531
Acquisition Source
Legacy CDMS
Document Type
Other
Authors
Kemp, Richard H.
(National Advisory Committee for Aeronautics. Aircraft Engine Research Lab. Cleveland, OH, United States)
Date Acquired
September 27, 2016
Publication Date
January 1, 1943
Subject Category
Nonmetallic Materials
Distribution Limits
Public
Copyright
Work of the US Gov. Public Use Permitted.
No Preview Available