NASA Logo

NTRS

NTRS - NASA Technical Reports Server

Back to Results
A Screening Method Using Pulsed-Power Combined with Infrared Imaging to Detect Pattern Defects in Bulk Metal Foil or Thin Film ResistorsBulk metal foil and thin film resistors occasionally contain localized defects within the etched resistor pattern. Common defects of this type include in-line constrictions referred to as notches, unremoved resistor material bridges between adjacent pattern lines, and embedded non-conductive particles in the resistor material. Such defects are prone to fracture due to thermomechanical fatigue during powered operation, especially power cycling, resulting in positive resistance change and open circuit failure modes. Common screening methods of optical microscopy, short time overload power tests (e.g., 6.25x rated power for 5 seconds) and burn-in (e.g., 1.5x rated power for 100 hours) are useful, but they are not always effective at removing devices with such defects. An improved method has been developed to screen for localized resistor pattern defects. The method involves the application of brief, high power electrical pulses at a low duty cycle while inspecting the resistor with a high resolution, high speed infrared camera. The following test conditions were found to be suitable for this purpose: 6.25x rated power, 1 to 5 pulses, 50 ms pulse width and 10% duty cycle. During the power pulsing, localized constrictions in the resistor pattern are identifiable as hot spots via the infrared camera. Reject criteria can be established based on observations of hot spots. To assess its effectiveness, a total of two hundred eighty (280) surface mount foil resistors (40 each from 7 different lots) were screened using this infrared technique. The screening identified twenty-nine (29) resistors with significant hot spots in the resistor pattern. All 280 resistors were then subjected to an industry standard 10,000 hour life test at 1x rated power at 70°C with power cycled for 90 minutes on and 30 minutes off. During life testing, three resistors exhibited positive resistance change failure mode. All three failures were due to thermomechanical fatigue failure of localized bridge defects at the locations identified via infrared screening. The results of this evaluation illustrate the benefits of the pulsed-power infrared detection screening technique to identify reliability suspect foil or thin film resistors that may escape common screening methods.
Document ID
20180007084
Acquisition Source
Goddard Space Flight Center
Document Type
Conference Paper
Authors
Brusse, Jay A.
(Arctic Slope Regional Corp. (ASRC) Federal Beltsville, MD, United States)
Panashchenko, Lyudmyla
(NASA Goddard Space Flight Center Greenbelt, MD, United States)
Date Acquired
October 30, 2018
Publication Date
October 9, 2018
Subject Category
Electronics And Electrical Engineering
Report/Patent Number
GSFC-E-DAA-TN58702
Meeting Information
Meeting: Space Passive Component Days (SPCD 2018)
Location: Noordwijk
Country: Netherlands
Start Date: October 9, 2018
End Date: October 12, 2018
Sponsors: European Space Agency, Centre National d'Etudes Spatiales (CNES)
Funding Number(s)
CONTRACT_GRANT: NNG13CR48C
Distribution Limits
Public
Copyright
Public Use Permitted.
Keywords
screening
No Preview Available